17–2

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

ALARM RELAYS

CHAPTER 17: MISCELLANEOUS COMMANDS

Note

The S-RING OPEN event is not supported in the MultiLink ML1600 Ethernet Switch.

17.1.2 Configuring Alarm Relays through the Command Line Interface

To customize these capabilities, the ML1600 provides additional software capabilities and
commands for configuring the alarm relays.

The

alarm

command enters the alarm configuration mode

alarm

The

add

command enables alarm action in response to the specified event ID.

add event=<event-id|list|range|all>

The

period

command sets the duration of relay action for the momentary type signal.

This may be needed to adjust to the behavior of the circuit or relay. The time is in seconds,
with a default of 3.

period time=<1..10>

The

del

command disables alarm action in response to the specified event ID.

del event=<event-id|list|range|all>

The

alarm

command globally enables or disables the alarm action.

alarm <enable|disable>

The

show alarm

command displays the current status of alarm system

show alarm

An example of setting up the external relays and alerts is shown below.

Table 17–1: Pre-defined conditions for the relay

Event ID

Description

Signal type

1

S-RING OPEN

(see note below)

SUSTAINED

2

Cold Start

MOMENTARY

3

Warm Start

MOMENTARY

4

Link Up

MOMENTARY

5

Link Down

MOMENTARY

6

Authentication Failure

MOMENTARY

7

RMON Rising Alarm

MOMENTARY

8

RMON Falling Alarm

MOMENTARY

9

Intruder Alarm

MOMENTARY

10

Link Loss Learn Triggered

MOMENTARY

11

Broadcast Storm Detected

MOMENTARY

12

STP/RSTP Reconfigured

MOMENTARY

13

Power Supply A Failed

SUSTAINED

14

Power Supply B Failed

SUSTAINED