CHAPTER 17: MISCELLANEOUS COMMANDS

ALARM RELAYS

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

17–3

Alarm relays (continued)

ML1600(alarm)##

add event=2

Alarm Event(s) Added: 2

ML1600(alarm)##

show alarm

Alarm Events Configuration

--------------------------

Alarm Status: DISABLED

Relay Closure Time Period: 5 Seconds

EventId

Description

Mode

------------------------------------------

1

S-RING OPEN

SUSTAINED

2

Cold Start

MOMENTARY

3

Warm Start

MOMENTARY

4

Link Up

MOMENTARY

5

Link Down

MOMENTARY

6

Authentication Failure

MOMENTARY

7

RMON Raising Alarm

MOMENTARY

8

RMON Falling Alarm

MOMENTARY

9

Intruder Alarm

MOMENTARY

10

Link Loss Learn Triggered

MOMENTARY

11

Broadcast Storm Detected

MOMENTARY

12

STP/RSTP Reconfigured

MOMENTARY

ML1600(alarm)##

alarm enable

Alarm system Enabled

ML1600(alarm)##

show alarm

Alarm Events Configuration

--------------------------

Alarm Status: ENABLED

Relay Closure Time Period: 5 Seconds

EventId

Description

Mode

------------------------------------------

1

S-RING OPEN

SUSTAINED

2

Cold Start

MOMENTARY

3

Warm Start

MOMENTARY

4

Link Up

MOMENTARY

5

Link Down

MOMENTARY

6

Authentication Failure

MOMENTARY

7

RMON Raising Alarm

MOMENTARY

8

RMON Falling Alarm

MOMENTARY

9

Intruder Alarm

MOMENTARY

10

Link Loss Learn Triggered

MOMENTARY

11

Broadcast Storm Detected

MOMENTARY

12

STP/RSTP Reconfigured

MOMENTARY

ML1600(alarm)##

alarm disable

Alarm system Disabled

ML1600(alarm)##

del event=1,3,5,7

Alarm Event(s) Deleted: 1, 3, 5, 7

(continued on next page)