MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

ML1600 SOFTWARE UPDATES

CHAPTER 1: INTRODUCTION

Z

Select the switch to upgrade.
Ensure you have system administration privileges available on the
switch.

Z

Open a EnerVista Secure Web Management software session with
the switch by typing in the following URL:

https://<IPaddress of the switch>

Z

If using FTP, save the configuration before proceeding.
GE Multilin recommends a two-step update:
• save the configuration to the ftp server
• load the new image and restart the switch (refer to Saving

Configuration on page 5–19 for details on saving the
configuration).

Z

Load the new software as shown below.

As the file is being loaded, the software will display the transfer in progress window.

Z

Reboot the switch when the transfer is complete.
After reboot, the software is ready for use.

Z

If using TFTP, save the configuration before proceeding.
GE Multilin recommends a two-step update:
• Save the configuration to the TFTP server.
• Load the new image and restart the switch (refer to Saving

Configuration on page 5–19 for details on saving the
configuration).