CHAPTER 17: MISCELLANEOUS COMMANDS

ALARM RELAYS

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

17–5

17.1.3 Configuring Alarm Relays with EnerVista Secure Web Management Software

To customize the alarm relays,

Z

select the Configuration > Alarm menu item.

Each alarm can be enabled or disabled form the screen shown above. All alarms can be
enabled or disabled using the Alarm Status drop down menu. Relay closure times can be
set using the drop down menu.

Z

After changing the Alarm settings, save the configuration using the
save icon (

).

Alarm relays (continued)

ML1600(alarm)##

show alarm

Alarm Events Configuration

--------------------------

Alarm Status: DISABLED

Relay Closure Time Period: 5 Seconds

EventId

Description

Mode

------------------------------------------

1

S-RING OPEN

NOT ENABLED

2

Cold Start

MOMENTARY

3

Warm Start

NOT ENABLED

4

Link Up

MOMENTARY

5

Link Down

NOT ENABLED

6

Authentication Failure

MOMENTARY

7

RMON Raising Alarm

NOT ENABLED

8

RMON Falling Alarm

MOMENTARY

9

Intruder Alarm

MOMENTARY

10

Link Loss Learn Triggered

MOMENTARY

11

Broadcast Storm Detected

MOMENTARY

12

STP/RSTP Reconfigured

MOMENTARY

ML1600(alarm)##

exit

ML1600#