CHAPTER 7: ACCESS USING RADIUS

CONFIGURING 802.1X THROUGH THE COMMAND LINE INTERFACE

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

7–5

and integer values can range from 0 to 10. The

transmit

argument is optional and

represents the transmit period. This is the time in seconds the authenticator waits to
transmit another request for identification from the supplicant. The default value is 30 and
values range from 1 to 65535 seconds

The

reauth

command determines how the authenticator (MultiLink switch) performs the

re-authentication with the supplicant or PC.

reauth port=<num|list|range> [status=<enable|disable>]
[period=<10-86400>]

The port argument is mandatory and sets the ports to be configured. The status argument
is optional and enables/disables re-authentication. The period argument is optional and
represents the re-authentication period. This is the time in seconds the authenticator waits
before a re-authentication process will be performed again to the supplicant. The default
value is 3600 seconds (1 hour), and values range from 10 to 86400 seconds.

The

show-stats

command displays 802.1x related statistics.

show-stats port=<num>

The

trigger-reauth

command manually initiates a re-authentication of supplicant.

trigger-reauth port=<num|list|range>