Maps and Registers

FPGA Registers

144

PENT/ATCA−717

Clock Synchronization Interface Registers

These registers are related to the clock synchronization building block of the blade. These
registers are primarily used to:

aa

S Select system clock 1 or 2 from back plane

S Select system or reference clock for DPLL input

S Enable reference clocks A and B to the backplane

S Select recovered clock source

S Determine programmable reference clock divider value

S Determine reference clock pulse width

Note:

a

Motorola offers a device driver to access the clock synchronization interface.

Instead of directly accessing the clock synchronization interface via the registers
described in this section, it is strongly recommended to use this driver. Ask your local
Motorola representative for details.

a

The following clock synchronisation interface registers are available:

Table 28:

Clock Synchronisation Interface Registers

Index Address

Register

30

16

SPI Address register

31

16

SPI Data register

32

16

DPLL Input Select and Control register

33

16

Reference Clock Divider register

34

16

Lower Reference Clock Divder register

35

16

Upper Reference clock Divider register

36

16

Reference Clock Pulse Width register

SPI Interface Registers

The used DPLL device ACS8525 from SEMTECH provides a Serial Peripheral Interface
(SPI) which provides external access for device setup and controlling. Software that
wishes to access the DPLL device has to first set the desired address in the SPI Address
register followed by either a read or write access to the SPI data register. For details about
configuring the DPLL device, refer to its data sheet.