Motorola ATCA-717 User Manual

Page 38

Advertising
background image

Installation

Requirements

38

PENT/ATCA−717

Requirement

Non−Operating

Operating

Rel. Humidity

5% to 95% non
condensing at +40

°

5% to 95% non condensing
at +40

°C

Altitude

–300 m to +3,000 m

–300 m to +13,000 m

Vibration

20 to 2000Hz

2 g(RMS) random

2 g(RMS) random

Shock

5 g/30 ms half sine

15 g/11 ms half sine

Free Fall

aa

1,200 mm/all edges and
corners (packed state)
100 mm/3 axis (unpacked)

To guarantee proper blade operation, you have to make sure that the temperatures at the
following locations are not exceeded. If not stated otherwise, the temperatures should be
measured by placing a sensor exactly at the given locations.

aaa

Location No.

Component

Temperature Limit

1

Pentium M CPU

1)

100

°C

2

Intel 82540EM Gbit Ethernet controller

100

°C

3

Intel 6300ESB Southbridge

105

°C

4

Lithium battery

70

°C

5

Intel 82546EB/GB Dual Gbit Ethernet
controller

90

°C

6

Electrolytic capacitor CE9902

100

°C

7

Electrolytic capacitor CE9903

100

°C

8

Ericsson DC/DC converter

90

°C

9

QM48T DC/DC converter

115

°C

a

(105

°C coated blade variant)

10

Power MOSFET IRF 6603

105

°C

1)

Temperature must be measured via on−die sensor which can be accessed via IPMI

Advertising