Motorola ATCA-717 User Manual

Page 94

Advertising
background image

BIOS

BIOS Messages

94

PENT/ATCA−717

Message

Corrective Action

Explanation

a

Keyblade error

Keyblade not working

Check for correct keyblade
connection.

Keyblade error nnn

BIOS discovered a stuck
key and displays scan code
nn for stuck key

Replace keyblade, check for
stuck keys

Operating system not found

Operating system cannot
be located on either drive
A: or drive C:.

Enter setup and check if
fixed disk and drive A: are
properly identified.

Parity Check 1 nnnn

Parity error found in
system bus. BIOS attempts
to locate address nnnn and
display it on screen. If it
cannot locate the address, it
displays ????.

Check for correct memory
module types.

Parity Check 2 nnnn

Parity error found in
system bus. BIOS attempts
to locate address nnnn and
display it on the screen. If it
cannot locate the address, it
displays ????.

Check for correct memory
module types.

Press <F1> to resume, <F2>
to setup

Displayed after any
recoverable error message

Press <F1> to start boot
process or <F2> to enter
setup and change any
settings.

Previous boot incomplete −
Default configuration used

Previous POST did not
complete successfully.
POST loads default values
and offers to run setup. If
failure was caused by
incorrect values and they
are not corrected, the next
boot will likely fail.

Run setup to restore
original configuration. This
error is cleared the next
time the system is booted.

Real time clock error

Real−time clock fails BIOS
test

May require blade repair

Resource allocation
conflict on motherblade −
Run Configuration Utility

Possible interrupt or
interface resource conflict.

Run ISA or EISA
Configuration Utility to
resolve resource conflict.

Shadow RAM Failed at
offset: nnnn

Shadow RAM failed at
offset nnnn of the 64k block
at which error was
detected.

Contact your local sales
representative or FAE for
further support.

nnnn Shadow RAM Passed

nnnn is amount of shadow
RAM in KBytes
successfully tested

None

Advertising