5

Table 1 - 2. Exterior Rear (SW2 and SW3) DIP Switch Settings

Upper DIP Switches:

SELECTION

1

2

3

4

5

6

7

8

DEFAULT

Baud Rate

38400

ON ON OFF

19200

ON OFF ON

9600

ON OFF OFF

9600

4800

OFF ON ON

2400

OFF ON OFF

1200

OFF OFF ON

Software Ctrl

OFF OFF OFF

Data Bits

7 Data Bits

ON

8 Data Bits

OFF

8 Data Bits

Stop Bits

2 Stop Bits

ON

ON Stop Bit

OFF

1 Stop Bit

Parity

Even

ON OFF

Odd

OFF ON

None

OFF OFF

None

Parallel Port

Centronics Mode

OFF

Centronics

IEEE-1284

ON

Advertising