010

Field ID number is outside range 0 to 999.

011

Field length exceeds 2710.

012

Row field position is greater than maximum stock dimension.

013

Column field position is greater than maximum stock dimension.

014

Font style must be 1, 2, 3, 4, 10, 11, 15, 16, 17, 18, or 50.

015

Character rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree).

016

Field rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree).

017

Field restriction must be V (variable) or F (fixed).

018

Code page selection defined in field must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).

020

Vertical magnification must be 1 to 7 or 4 to 90 points for scalable font.

021

Horizontal magnification must be 1 to 7 or 4 to 90 points for scalable font.

022

Color must be A, B, D, E, F, N, O, R, S, T, or W.

023

Intercharacter gap must be 0 to 99 dots.

024

Field justification must be B (balanced), C (centered), E (end), L (left), or R (right).

025

String length is outside range 0 to 2710.

030

Bar code height must be at least 20 (English), 51 (Metric), 40 (Dots), and within supply dimensions.

031

Human readable option must be:

0

default

1

no CD or NS

5

NS at bottom, no CD

6

CD at bottom, no NS

7

CD and NS at bottom

8

no text

032

Bar code type is invalid.

033

Bar code density is invalid.

040

Line thickness must be 0 to 99 dots.

041

Line direction must be 0, 90, 180, or 270.

042

End row is invalid. Line segment or box end row is defined outside of printable area.

043

End column is invalid. Line segment or box end column is defined outside of printable area.

044

Dot pattern for line or box must be "".

045

Line length is defined beyond maximum length.

046

Line type must be S (segment) or V (vector).

051

Imaging mode in graphic header must be 0.

101

The format referenced by batch is not in memory.

102

Print quantity is outside range 0 to 32000.