Blade assembly replacement, Drive board replacement, Motor replacement – Monarch Instrument 9830TM User Manual

Page 75

Advertising
background image

9820/9830/9835 Service Manual

Model 926 Knife

68

TC9830SM Rev. B 7/98 Confidential

July 1998

J1

To Motor

J4

To 928 Stacker

J2

To Solenoid

J5

To Printer Daughter Board

J3

To Printer Control Board

Figure E-4. Drive Board Connector Locations.

Blade Assembly Replacement

1. Turn printer off.

2. Remove 928 Stacker Assembly. See Appendix D.

3. Remove three cover screws to gain access to the

Blade Assembly.

4. Note the position of the Blade Assembly in

relation to its mounting frame. This relationship is
critical to provide a straight cut from left edge to
right edge of tag.

5. Using an Allen wrench, remove two cap screws

that attach the knife unit to its mounting frame.

6. Disconnect solenoid at connector J2 on Drive

Board.

7. Remove the Knife Blade Assembly.

8. Reassemble in reverse order.

NOTE:

Carefully align the edge of the knife
assembly to the mounting frame. There
should be almost no variation side to side
on a cut tag (0.030 +/- 0.020). The
mounting hole closest to the operator panel
is slotted for this adjustment.

9. Adjust Blade Assembly. When a straight cut

across the tag has been achieved, lock down all
adjustments.

10. Run 50 - 100 tags to verify proper cut operation.

11. Replace the knife cover.

12. Attach the Stacker Assembly, see Appendix D.

13. Turn printer on and test for correct operation.

Drive Board Replacement

Replace the Drive Board using the following
procedure:

1. Turn printer off.

2. Remove the Stacker Assembly, see Appendix D.

3. Remove three cover screws to gain access to the

Drive Board.

4. Note the positions of all wiring harness

connections.

5. Disconnect each harness from the Drive Board.

6. Lift the Drive Board off its standoffs.

7. Reassemble in reverse order.

8. Attach the 928 Stacker Assembly and test for

correct operation.

Motor Replacement

1. Turn printer off.

2. Remove 928 Stacker Assembly. See Appendix D.

3. Remove three cover screws to gain access to the

motor.

4. Remove two motor mounting screws and remove

motor.

5. Remove knife motor wiring at motor connector.

6. Loosen the pulley set screw and remove pulley.

Make sure set screw is on flat of shaft.

7. Reassemble in reverse order.