9820/9830/9835 Service Manual

Diagnostics

20

TC9830SM Rev. B 7/98 Confidential

July 1998

Figure 4- 1. Test Labels

The first test label prints firmware version and current
printer configuration in I packet format (refer to the
printer’s Packet Reference Manual ).

NOTE:

Some reported settings may not be
configurable on a given printer:

A System Setup
B Supply Setup
C Print Control
D Monetary Formatting

E Control Characters
F Serial Comm Settings
G Backfeed Control
M Memory Allocation

The second label prints basic diagnostic information:

Total Inches Printed
Current Inches
+40 VDC Value (s/b 30-47)
Dot Resist (s/b 832 Ohms)

No of Bad Dots (s/b < 3)
Total RAM (Max 512K)
DIP Settings
Contrast Pot

Installed Options:

M

R
V
P
C
S
X

256K memory expansion
RS-232 option (Keypad)
Verifer
Peel
Cutter
Stacker
V5.2 sensing system

SERVICE DIAGNOSTICS

Service Diagnostics is initiated by setting the Lower
DIP switch 3 to the ON position before powering up.
At power-up, 000 is displayed on the control panel.

Two Service Diagnostic modes are available:

Data Dump Mode

Diagnostics Test Mode

Off-line Diagnostics Tests

Serial Loop Back Test

Parallel Port Timeout Test
Test Label
Virgin Reset

SENDFILE Diagnostic Tests

Test Label
Sensor Display
Service Totals
Immediate Commands
Job Request
Printer Interactive Mode

Supporting Hardware Accessories Required:

SENDFILE and Flashloader requires a laptop

or PC connected to the printer via a serial
cable. PC should be capable of
communicating at 38.4 baud.

Serial Loop Back Test requires Loop Back

Plug #114271.

Accessing Diagnostic Modes

To use the different modes available in Service
Diagnostics, you must have lower DIP switch 3 turned
on and the display reads 000.

From the 000 display, press Feed and Clear at the
same time until you see 001 (data dump mode),
002 (serial loop back test), or
003 (parallel port test). Each mode is activated by
pressing Pause.

Data Dump Mode

To use data dump mode:

1. Set lower DIP switch 3 to ON. The display reads

000.

2. Press Feed and Clear at the same time. The

display changes to 001 (Mode 1).

3. Press Pause to enter data dump mode. Two

blank labels feed and the display reads 111.

4. Download the data stream you want to dump (print

on a label).

5. Press Feed and Clear at the same time to exit

data dump mode. The display reads 000.

Data dump mode captures all data being sent to the
printer and holds it in a buffer. No data is acted upon
(ex: Immediate commands or Job request packets).
Once the buffer is full, a label automatically prints with
the downloaded data printed on it. You must press
Feed to print a label if the amount of data sent does
not fill the buffer to the required level.

NOTE:

If you are sending data down through
SENDFILE, be sure to disable ENQ. This