Bi-cell emitter removal, Upper supply guide removal, Printhead module removal – Monarch Instrument 9830TM User Manual

Page 37: Ribbon spool assembly removal, Ribbon roller assembly removal, Dc ribbon motor removal

Advertising
background image

9820/9830/9835 Service Manual

Service Procedures

30

TC9830SM Rev. B 7/98 Confidential

July 1998

ribbon motors and print assembly.

Figure 6-4. Print Assembly

TOOLS/MATERIALS REQUIRED:

Phillips Screwdriver

Flat-head Screwdriver

Ribbon spool intermediate gear retaining clip.

Bi-Cell Emitter Removal

Figure 6-5. Bi-Cell Emitter Removal

1. Using fingers, release emitter cover from the

emitter housing. Slide the emitter out of the
housing. See Figure 6-5.

2. Remove the connector from the sensor circuit

board.

3. Carefully work the sensor harness through the

upper supply guide openings and through the
print assembly opening.

4. Lay the sensor circuit board and harness aside.

Upper Supply Guide Removal

1. Remove bi-cell emitter from the upper supply

guide.

2. Gently pry the supply guide from the pin and

remove it.

Printhead Module Removal

1. Remove the printhead ribbon cable connector at

the printhead end.

2. Remove three printhead module screws, as

shown in Figure 6-4.

3. Remove the printhead module and lay it aside to

prevent it from being damaged.

4. Carefully work the printhead cable back through

the exposed cable slot, and lay it aside.

Ribbon Spool Assembly Removal

1. Remove the C clip at the outer shaft end.

2. Slide spindle off shaft.

3. Reassemble in reverse order.

Ribbon Roller Assembly Removal

1. Remove the screw at the end of the roller shaft.

2. Slide the serrated roller and eccentric adjuster off

the end of the shaft.

3. Reassemble in reverse order.

4. Adjust ribbon tension. See Chapter 5.

DC Ribbon Motor Removal

1. Locate the two patterns of three recessed screws

on the front side of the print module casting.

2. Mark each motor so they aren’t interchanged

when reassembling.

3. Remove the three screws from each pattern while

holding the ribbon motor so it doesn’t fall.

4. Unplug the single wire from the Control Board

Assy.

Cover Tab

Advertising
This manual is related to the following products: