Feed assembly, Print assembly removal, Latch fascia removal – Monarch Instrument 9830TM User Manual

Page 38: Warning, Platen module removal

Advertising
background image

Service Procedures

9820/9830/9835 Service Manual

July 1998

TC9830SM Rev. B 7/98 Confidential

31

Print Assembly Removal

1. Remove two screws holding pivot retainers to the

frame.

2. Lift the upper supply guide and remove the

retainer pins from the upper supply guide.

3. Remove the magnet from the tunnel housing on

the side facing the Control Board Assy. See
Figure 6-6. Save the magnet.

Figure 6-6. Print Assembly Plate & Printhead

Module.

4. Reassemble in reverse order.

5. Adjust ribbon tension. See Chapter 5.

FEED ASSEMBLY

Maintenance of the Feed Assembly involves:

removing the latch fascia and platen module.

replacing the platen module.

removing the sensor and lower supply guide.

replacing the bi-cell sensor and supply guide.

TOOLS/MATERIALS REQUIRED:

Phillips Screwdriver

Flat-head Screwdriver

Ribbon spool intermediate gear retaining clip.

Latch Fascia Removal

1. Remove cover housing.

2. Remove snap pin from rear latch fascia by prying

gently outward with a screwdriver.

WARNING

Leave the printhead latched to hold the latch knob in

place, or it may fly off and cause harm.

Figure 6-7. Latch Removal

3. With the printhead latched, remove the latch

fascia. See Figure 6-7.

4. Carefully unlatch and raise printhead.

5. Pull latch knob away from platen frame until the

stop tab disengages from the frame.

6. Rotate latch knob counterclockwise until all spring

tension is relieved.

7. Remove latch knob and spring.

8. Remove the front exit door by lightly pressing one

side, until the hinge pin clears the platen frame.

9. Reassemble in reverse order.

Platen Module Removal

1. Remove the backing paper deflector.

2. Remove the three phillips screws that hold the

feed module to the printer base.

3. Lift up on the outboard side of the platen module

to allow the platen roller gear to clear the
printhead alignment bracket.

4. Rotate the platen module counterclockwise to

make room for removal of the platen assembly.

CAUTION

The sensor harness limits platen rotation. Be careful

not to damage the harness.

Latch Knob

Spring

Pivot Retainer

Magnet

Advertising
This manual is related to the following products: