9820/9830/9835 Service Manual

Printer Overview and Installation

6

TC9830SM Rev. B 7/98 Confidential

July 1998

Lower DIP Switches:

SELECTION

1

2

3

4

5

6

7

8

DEFAULT

Flow Control

XON/XOFF

ON OFF

RTS/CTS

OFF ON

DTR

OFF OFF

DTR

Diagnostics

Normal Run Mode

OFF

Normal

Diagnostics Mode

ON

Verifier

No Verifier

OFF

No Verifier

Verifier Installed

ON

Supply Type/ Sensing

Die Cut or Edge Aperture (edge sensor)

OFF OFF

Black Mark (center sensor)

OFF ON

Die Cut

Continuous (no sensor)

ON OFF

Center Aperture (center sensor)

ON ON

Ribbon

Transfer

OFF

Transfer

Direct

ON

Feed Mode

Continuous

OFF

Continuous

On-Demand

ON

NOTE:

DIP Switches for Version 5.2 or greater are shaded.