July 1998

POWER TRANSFORMER
ASSEMBLY

Maintenance of the Power Transformer involves

removing/reassembling the power

transformer.

removing/reassembling the bridge rectifier.

removing/reassembling the AC Inlet.

TOOLS REQUIRED:

Longnose Pliers

Phillips Screwdriver

Transformer Removal

CAUTION

You must remove several wires from the Bridge

Rectifier, AC Inlet module, and the Control Board

Assembly power connector. It is crucial to reconnect

the wires properly when replacing the transformer.

Figure 6-1. Transformer Wiring Diagram

1. Remove four bridge rectifier wires as shown in

Figure 6-1.

2. Remove power connector CN6 from the Control

Board Assembly. (See Appendix C for location of
connectors.)

3. Remove six transformer wires from the AC Inlet

module.

4. Remove four transformer base screws.

5. Lay the two grounding wires aside so they do not

snag when replacing the transformer.

6. Remove the transformer.

7. Reassemble in reverse order.

Bridge Rectifier Removal

Figure 6-2 Bridge Rectifier (Four Wires)

CAUTION

The bridge rectifier has four wire connections. See

Figure 6-2. Reconnect the black and red wires

properly when replacing these wires or the printer

could be damaged (voltages vary).

1. Remove the four wires and single retainer screw

located in the center of the rectifier.

2. Remove the bridge rectifier.

3. Reassemble in reverse order.

AC Inlet Removal

6-3 . Bridge Rectifier (Four Wires)

The AC Inlet has six wires coming from the
transformer and one ground wire. Reconnect the wires
properly when replacing this part (voltages vary).

CN6

Bridge Rectifier

Connection
to AC Inlet

Transformer