9820/9830/9835 Service Manual

Model 928 Stacker

64

TC9830SM Rev. B 7/98 Confidential

July 1998

removed from the stacker. Be careful not to lose
the spring.

17. Slide the front main frame off the tamper plate

shaft and gently pull it clear of the stacker.

18. The old lower transport assembly should now be

held in place by the four remaining plastite screws
on the rear main frame (118475).

19. Remove 4 screws holding the assembly in place,

and remove the lower transport assembly.

20. Install the replacement kit.

21. Reassemble in reverse order.

Replace DC Motor

1. Unplug stacker power and stacker-to-knife cable.

2. Remove rear, back, and side covers.

3. Disconnect motor wiring harness at motor

terminals 1 and 2.

4. Remove four motor mounting screws, belt, and

motor assembly.

5. Reassemble in reverse order.

Replace Stepper Motor

1. Unplug stacker power and stacker-to-knife cable.

2. Remove rear, back, and side covers.

3. Loosen set screws and remove belt speed

adjustment knob.

4. Remove belt adjustment potentiometer mounting

nut and washer.

5. Remove four screws and electronics cover.

6. Disconnect motor wiring harness at control board

connector P1.

7. Remove four motor mounting screws, belt, and

motor assembly.

8. Reassemble in reverse order.

Replace Stacker Sensors

The stacker full and stacker jam sensors share the
same wiring harness, so replace as an assembly.

1. Unplug stacker power and stacker-to-knife cable.

2. Remove screw attaching stacker full sensor to

stacker bed.

3. Remove 2 clips holding sensor wiring harness to

the stacker bed.

4. Thread sensor cable through frame to control

board.

5. Loosen set screws and remove belt speed

adjustment knob.

6. Remove 4 retaining screws and electronics cover.

7. Remove 4 screws holding control board to

standoffs.

8. Slide sensor out of transport mounting and thread

sensor cable through frame back to control board.

9. Move control board back to expose sensor wiring

harness connector.

10. Disconnect wire harness from control board

connector CN3 and remove sensor.

11. Reassemble in reverse order.

Replace Power Supply

1. Unplug stacker power and stacker-to-knife cable.

2. Loosen set screws and remove belt speed

adjustment knob.

3. Remove belt adjustment potentiometer mounting

nut and washer.

4. Remove 4 retaining screws and electronics cover.

5. Remove four power supply mounting screws.

6. Tilt power supply up to disconnect wiring harness

at connectors J1 and J2.

7. Remove power supply.

8. Reassemble in reverse order.

Replace Control Board

1. Unplug stacker power and stacker-to-knife cable.

2. Loosen set screws and remove belt speed

adjustment knob.

3. Remove belt adjustment potentiometer mounting

nut and washer.

4. Remove 4 retaining screws and electronics cover.

5. Disconnect harness connectors at control board

connectors J1, J2, and J3.

6. Remove the four screws holding the control board

to the standoffs.

7. Disconnect power supply harness at control board

connector CN1.

8. Remove control

board.

9. Reassemble in

reverse order.

Figure D- 6. Power Supply/Control Board.