9820/9830/9835 Service Manual

Model 928 Stacker

62

TC9830SM Rev. B 7/98 Confidential

July 1998

Table D- 6. Power Supply Connector J1

Connector J1 Pin

Color

To

1 GND

2 N/C

3

Black

On/Off Switch

4 N/C

5

White

AC Inlet

Figure D- 1. Stacker Control Board.

LUBRICATION

The stacker should be lubricated whenever the idler
shafts are replaced.

NOTE:

Do not get lubricant on stacker rollers or
belts; performance could be adversely
affected.

1. Turn stacker and printer off.

2. Remove stacker from knife assembly.

3. Remove the stacker rear and side covers.

4. Apply silicon lubricant to the two bearing on the

rear frame and two bearings on the front frame.
See Figure D-2.

5. Replace the stacker covers.

6. Reattach stacker to knife.

7. Turn on printer and stacker and test for correct

operation.

Figure D- 2. Stacker Lubrication Points.

MAINTENANCE
PROCEDURES

Use the illustrations provided and the Stacker
Illustrated Parts Breakdown for assistance in
performing maintenance. Maintenance procedures for
the stacker are described below.

Note the following general safety reminders before
servicing the stacker. Additional Warnings and
Cautions are provided where appropriate as they
apply to specific procedures.

WARNING

Never perform maintenance on the stacker with the

power cord connected. Doing so exposes points

where AC voltages are present. Reattach power cord

only when test procedures indicate that power is

required.

CAUTION

Static electricity can damage stacker parts. Use a
static ground wrist strap.

Bearings