Lower Supply Guide
Replacement

1. Reinstall sensor harness through retainer loops.

2. Align guide frame with notches in platen frame.

3. Press down on guide frame until latches engage

the platen frame.

SUPPLY HOLDER

TOOLS/MATERIALS REQUIRED:

Phillips Screwdriver

Flat-head Screwdriver

Supply Holder Removal

1. Pull upward on supply holder and lift it away from

the frame.

2. To replace the supply holder guides:

Remove screw from the washer and gear.

Pull front guide up and out of frame and

replace.

Pull back guide up and out of frame and

replace.

Move front and back guides to the center and

install supply gear and washer with the screw.

3. Insert the supply holder into the main frame and

push downward.

PLATEN MOTOR

Disconnect the wires from the AC Inlet to gain access
to the stepper motor connector. If you have problems
removing the motor (access is difficult), you must
remove the Control Board Assy.

TOOLS REQUIRED:

Phillips Screwdriver, Magnetic

Platen Motor Removal

1. Remove Control Board Assy.

2. Remove four screws from platen motor housing.

3. Reassemble in reverse order.

4. Adjust platen motor gear. See Chapter 5.

PEEL MODULE

Maintenance to the Peel Module includes replacement
of the motor and peel roller.

NOTE:

The peel roller is removed in the same
manner as the platen rollers.

TOOLS REQUIRED:

Phillips Screwdriver

Flat-head Screwdriver

Peel Module Removal

1. Remove printer housing.

2. Unload supply.

3. Raise Printhead and retain it in the up position.

4. Disconnect Peel Motor wiring connector at

motor.

5. Remove On-Demand Sensor wiring connector at

sensor and release wiring from the door
assembly.

6. Remove supply backing exit door assembly.

7. Remove peel module paper exit chute.

8. Remove three screws attaching the peel module

to the platen module.

9. Remove Peel Module through the end of the

printer.

10. Reassemble in reverse order.

Peel Motor Replacement

1. Remove Peel Module.

2. Carefully pry peel motor gear from shaft.

3. Remove three motor mounting screws and

remove motor.

4. Reassemble in reverse order.