11

MLDV Series Gas Fireplace

VENTING INSTALLATION

OPTIONAL TOP VENT APPLICATION

The appliance is shipped as a rear vent unit. If the installation layout
requires the unit to be a top vent configuration, the appliance can
be converted by following the steps below.
When removing and refitting the plates and adapter, be sure the
associated gaskets are undamaged and refitted as required.
1. Remove the eight (8) screws securing the flue pipe adapter to

the fireplace body. Figure 7

. Set the flue pipe adapter aside, complete with the gasket. Do

not damage the gaskets as the adapter and gasket must be
refitted.

3. Remove the eight (8) screws securing the flue pipe cover to the

top of the intake box and remove the cover and gasket. Figure
7

4. Remove six (6) screws securing the flue pipe to the back of the

intake box and remove the pipe and gasket. Figure 8

5. Replace the flue pipe to top of firebox. Ensure the gasket is in

place and undamaged. Secure with six (6) screws. Figure 9

6. Place the flue pipe cover and gasket removed in Step 3 over

the flue opening in bottom of the intake box.

7. Refit the flue pipe adapter and gasket to the top of fireplace.

Secure the adapter with six (6) screws removed in Step 1.

FP1991
remove screws

Screws

Flue Pipe
Cover

Flue Pipe
Adapter

FP1991

Figure 7 -
Remove 16 screws from Flue Pipe Adapter and
Flue Pipe Cover

FP1992
remove flue pipe

Flue Cover

Screws

Flue Pipe

FP199

Figure 8 -
Remove Flue Pipe

FP1993
replace flue pipe

Screws

Flue Pipe

FP1993

Figure 9 -
Attach Flue Pipe to Top Vent Configuration

After conversion to top vent
configuration, the 5" (127 mm)
flue pipe should be concentric
with the 8" (203 mm) outer collar
within 1/4".