Mldv series gas fireplace – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 23

Advertising
background image

75D0004

3

MLDV Series Gas Fireplace

FP1183
max height

VERTICAL (THROUGH-THE-ROOF) APPLICATIONS (continued)

This Gas Fireplace has been approved for,

•

Vertical installations up to 40' (1 m) in height. Up to a 10' (3 m) horizontal vent run can be installed

within the vent system using a maximum of two 90° elbows. Figure 30

VENTING INSTALLATION

Figure 31 -
Maximum Elbow Usage

•

Up to two 45° elbows may be used within the horizontal

run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by
18" (450 mm).

Example: Maximum horizontal length
No elbows

= 10’ (3 m)

1 x 45° elbows

= 8.5’ (.6 m)

 x 45° elbows

= 7’ (.1 m)

•

A minimum of an 8' (.5 m) vertical rise is required.

•

Two sets of 45°elbows offsets may be used within the

vertical sections. From 0 to a maximum of 8' (.5 m)
of vent pipe can be used between elbows. Figure 31

•

Determine the roof pitch and use the appropriate

starter kit for offset installation.

•

The maximum angular variation allowed in the system

is 70°. Figure 31

•

The minimum height of the vent above the highest

point of penetration through the roof is ' (610 mm).

Example:

Elbow 1

= 90°

Elbow 

= 45°

Elbow 3

= 45°

Elbow 4

= 90°

Total Angular Variation

= 70°

10'

Maximum

10'

Maximum

40' Max. Height

8' Min. Height

Support Straps
Every 3'

Figure 30 -
Support Straps for Horizontal Runs

40' Max. Height

8' Min. Height

Support Straps
Every 3'

FP1183

1
2
3
4

1
2
3
4

FP1179

max bends