VERTICAL (THROUGH-THE-ROOF) APPLICATIONS (continued)

This Gas Fireplace has been approved for,

Vertical installations up to 40' (1 m) in height. Up to a 10' (3 m) horizontal vent run can be installed

within the vent system using a maximum of two 90° elbows. Figure 30

VENTING INSTALLATION

Figure 31 -
Maximum Elbow Usage

Up to two 45° elbows may be used within the horizontal

run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by
18" (450 mm).

Example: Maximum horizontal length
No elbows

= 10’ (3 m)

1 x 45° elbows

= 8.5’ (.6 m)

 x 45° elbows

= 7’ (.1 m)

A minimum of an 8' (.5 m) vertical rise is required.

Two sets of 45°elbows offsets may be used within the

vertical sections. From 0 to a maximum of 8' (.5 m)
of vent pipe can be used between elbows. Figure 31

Determine the roof pitch and use the appropriate

starter kit for offset installation.

The maximum angular variation allowed in the system

is 70°. Figure 31

The minimum height of the vent above the highest

point of penetration through the roof is ' (610 mm).

Example:

Elbow 1

= 90°

Elbow 

= 45°

Elbow 3

= 45°

Elbow 4

= 90°

Total Angular Variation

= 70°

10'

Maximum

10'

Maximum

40' Max. Height

8' Min. Height

Support Straps
Every 3'

Figure 30 -
Support Straps for Horizontal Runs

40' Max. Height

8' Min. Height

Support Straps
Every 3'