Mldv series gas fireplace – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 5

Advertising
background image

75D0004

5

MLDV Series Gas Fireplace

PRODUCT FEATURES

This appliance has been certified for use with
either natural or propane gas. See appropriate
data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bed-

sitting room installations.

The appliance must be installed in accordance

with local codes if any. If none exist use the cur-
rent installation code. ANSI Z3.1/NFPA 54 in
the USA, CSA B149 in Canada.

This appliance is mobile home appr-oved.

The appliance must be properly connected to a

venting system.

The appliance is not approved for closet or

recessed installations.

PRODUCT SPECIFICATIONS

Figure 1 -
MLDV Series Fireplace
(Millivolt Control shown)

FP1984
MLDV components

Off/Pilot/On Knob

Hi/Lo Knob

On/Off/RS
Switch

Ignitor

5/8" Nailing
Flange

1/" Nailing
Flange

Insulation Board

FP1984

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certi-
fied without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installation at eleva-
tions above 4,500 feet (1,370 m).

GAS PRESSURES

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Max.Input Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

MLDV500NV

Nat.

34,000

,000

#33

MLDV500PV

LP

34,000

7,000

1.8 mm

MLDV500NSC Nat.

34,000

,000

#33

MLDV500PSC LP

34,000

7,000

1.8 mm

GAS SPECIFICATIONS & ORIFICE SIZE

Advertising