Mldv series gas fireplace, Warning – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 8

Advertising
background image

8

75D0004

MLDV Series Gas Fireplace

71” Minimum

Ceiling

12” Max.

Depth

14” Min.

From Opening

6” Min.

to Opening

FP1987

clearances

FP1988
Mantel clearances

116 "

9556QE"

14"

12"

10"

8"

Wall

Stud

Insulation
Board

FP1988

Top of Fire-
place Opening

CLEARANCES

CLEARANCES TO COMBUSTIBLES

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If
it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Figure 4 -
Side Wall and Ceiling Clearances

Figure 5 -
Mantel clearances.

6"

5"

3"

256O"

456O"

45°

356O"

1"

156O"

FP1949

mantel clearances

Fireplace
Opening

Wall

Combustible
Material Area

Side Wall

Combustible
Mantel

Top View

Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring,
the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.

Side View

W

ARNING