Mldv series gas fireplace, Remote wall mounted switch, Before installing the blower – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 31: Installing the blower, Warning, Do not connect wall switch 110v circuit

Advertising
background image

75D0004

31

MLDV Series Gas Fireplace

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18
Ga. wire may be used with this appliance. Attach the
wall switch in a junction box at the desired location
on the wall. Figure 44 Do not extend beyond the wall
switch wire length provided.
NOTE: Extended lengths of wire may cause the
fireplace not to function properly. Longer length
of wire is permitted if the wire is made out of
larger gauge (diameter) wire. Always check with
local code.

Figure 44 -
Wiring Diagram for Wall Switch

REMOTE WALL SWITCH INSTALLATION

OPTIONAL FAN/BLOWER SYSTEM
(BLOTBLDV)
Installation Instructions
Wiring

1. Before installing the blower, wire the receptacle into an elec-

trical circuit. This should be done before framing the fireplace.
Wire with minimum 60° C wire in accordance with prevailing
codes.

. Remove the external junction box cover by removing the

screw from the left side of the outside firebox wall. Junction box was installed at the factory.

3. The junction box cover has a factory installed “romex” style strain relief connector. After connecting

the wires, route the wire leads through this connector. Refer to the wiring diagram in Figure 45.

Before Installing the Blower

1. Always turn off the gas supply and allow the unit to cool down before proceeding.
. Clean the inside of the firebox (wall and floor), where the blower and wires will be installed. Make

sure the firebox wall and floor are clean and dry before mounting the blower.

Installing the Blower

1. Remove the lower access panel by pulling up and away from unit.
. Remove glass frame by releasing the two () latches (500 Model has three (3) latches) below the

firebox opening and lifting glass frame up and away from unit.

3. Remove logs.
4. Remove grate from engine by lifting up.
5. Remove hearth brick and wall brick panels.
6. Disconnect the gas line to the valve.
7. Remove screws securing engine base to firebox floor and lift engine up to remove.
8. Two () magnetic strips have been supplied to secure each blower to the firebox floor. Place on bot-

tom of each blower before installing. Figure 46

9. The blowers are to be inserted flat through the engine cutout in the firebox floor. Slide each blower

over to the sidewall location. Figure 47

FP1912
Junction box wiring
8/08

Figure 45 -
Junction Box Wiring Diagram

10V AC
60Hz

junction Box

Factory Supplied
Not Supplied

ON

OFF

OPTIONAL REMOTE

WALL SWITCH

ON

OFF

OPTIONAL REMOTE

WALL SWITCH

PILOT

HI

LO

ON

OFF

TH

TP

TH/TP

ON

OFF

RS

FP1980
Dv wiring diagram

W

ARNING

Do not connect wall
switch 110V circuit.

Advertising