Lighting pilot, Lighting pilot for the first time, Pilot – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 35: Mldv series gas fireplace, Warning, Danger

Advertising
background image

75D0004

35

MLDV Series Gas Fireplace

PILOT

OF

F

PI

LO

T

ON

FP1935
control knob pilot

Continued on next page

APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods
only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer

NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.

1. Depress and turn knob counterclockwise

to pilot

position.

. Depress fully and hold pilot gas knob. Depress

piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds. Release
and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and .

LIGHTING PILOT

Figure 52 -
Pilot Position

Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections

• Field made joints / gas shutoff valve

• Pilot

• Factory made joints

• Each joint or connection

• All joints on valve and control body

LIGHTING PILOT FOR THE FIRST TIME

OPERATING INSTRUCTIONS (MILLI-VOLT)

If using a soap and water
solution to test for leaks,
DO NOT spray solution onto
control body.

W

ARNING

Never check for gas leak with open
flame!

DANGER

The control has an interlock device that does not allow the lighting of the fireplace
up to the moment the safety device of the flame has not interrupted the gas flow.
After that period of time (when the magnet is closed), it is possible to start the
lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools
during this operation. Damaged knobs may result in serious injury.

W

ARNING

Advertising