Mldv series gas fireplace, Fp1953 rigid pipe, Venting installation – Monessen Hearth DIRECT VENT MLDV500 User Manual

Page 16: Rear wall vent installation (5" x 8" venting only), Fp1954 wall framing

Advertising
background image

16

75D0004

MLDV Series Gas Fireplace

Only one 45 degree elbow is allowed in these installations.

1. Rigid vent pipes and fittings have special twist-lock connections. Assemble the desired

combination of pipe and elbows to the appliance adapter.

Twist-Lock Procedure: The female ends of the pipes and fittings have three (3) locking

lugs (indentations). These lugs will slide straight into matching slots on the male end of
adjacent pipes and fittings. Push the pipe sections together and twist one section clockwise
approximately one-quarter turn until the sections are fully locked. Figure 15

. Refer to venting and termination instructions for further instructions.
3. Locate and cut the vent opening in the

wall. For combustible walls first frame in
opening.

Combustible Interior Walls: Cut a 1

1

/



"

x 10

1

/



" hole through the interior wall.

Combustible Exterior Walls: Cut a 10

1

/



"

x 10

1

/



" square hole through the exterior

wall frame. Figure 16

Noncombustible Walls: Hole opening

should be 8

1

/



" (16 mm) in diameter.

4. The center of the hole should align with

the center line of the horizontal rigid vent
pipe end. Allow 1/4" minimum rise per foot.
Figure 16

5. Apply a bead of non-hardening mastic

around the outside edge of vent cap. Posi-
tion the vent cap in the center of hole on the
exterior wall with the word "UP" on the vent
cap facing up. Insure proper clearance of
1" to combustibles is maintained. Attach
the vent cap with four (4) wood screws
supplied. Figure 17

VENTING INSTALLATION

FP1953
rigid pipe

Female Locking
Lugs

Male Slots

NOTE: Horizontal runs of
vent must be supported every
three feet (914 mm). Use wall
straps for this purpose.

Figure 15 -
Rigid Vent Pipe Connections

REAR WALL VENT INSTALLATION (5" x 8" VENTING
ONLY)

When installed as a rear vent unit, this appliance may be vented directly to
a termination located on the rear wall behind the appliance. Only an MHSC
brand termination is allowed for this application.

The maximum horizontal distance between the rear of the appliance

and the termination is 0" (508 mm). Figure 14

DVR584-600

Rear vent no elbows

2/99 djt

Maximum

0"

Top View Flat Installation

Figure 14 - Rear Vent Application,
Maximum Horizontal Distance

FP1954
wall framing

10

1

/



"

(67 mm)

10

1

/



"

(67 mm)

8

1

/



"

(16 mm)

Figure 16 -
Exterior Wall Framing Dimensions

Combustible Wall

Noncombustible

Wall

FP1954