Viewing system configuration – Intel SGI Altix 450 User Manual

Page 113

Advertising
background image

L2 Operation

007-4857-002

91

Once the L2 is running, you can telnet to the L2, or use an optional SGIconsole.

After the connection to the L2 controller is established, the following prompt appears, indicating
that the L2 is ready to accept commands:

olympic-101-L2>

Common operations are discussed in the subsections that follow.

Viewing System Configuration

You can use the L2’s config command to view the current system configuration from an IRU
level:

olympic-101-L2> config

L2 127.0.0.1: - 001 (LOCAL)

L1 127.0.0.1:0:0 - 001c31

L1 127.0.0.1:0:1 - 001c21

L1 127.0.0.1:0:2 - 001c11

L1 127.0.0.1:0:3 - 001c01

L2>

As shown above, config produces a list of IRUs and their locations in the system and the system
controller address of each IRU. This is similar to the output from using the config command on
the L1 with the addition of the L2 IP address, L1 connection, and L1 index.

The structure of the IRU address is as follows:

a.b.c.d:x:y

where:

a.b.c.d

is the IP address of the L2. (In the example above, the IP address is 127.0.0.1.)

x

connection number is only 0 for Altix 450

y

is the L1 index - the index identifies an IRU by its rack, type, and slot (001c01).
The structure of the IRU location is as follows:

rrrbss.p

where:

rrr

is the rack number.

Advertising