L2 Operation

007-4857-002

97

Subchannel 3C specifies Blade 3, CPU C.

Subchannel console0 Blade 0 console subchannel.

Subchannel console1 Blade 1 console subchannel.

The select command output: “console input: 001c01 console0” shows that the L2
will send console input to IRU 001c01 blade 0 and the console subchannel will be used.

To change the IRU that will be the system console, use the select <rack>.<slot>
command, where <rack> is the rack and <slot> is the slot where the IRU is located:

L2> select 1.1

console input: 001c01 console

console output: no filtered

console detection: L2 detected

To change the subchannel used on the selected IRU, use the select subchannel
<0A|0C|1A|1C>

command. (Use the select subchannel console to select the

current console as the subchannel of the IRU to be the system console.) For example, to select
blade 1, CPU A as the subchannel of the IRU to be the system console, enter the following:

L2> select subchannel 1A

console input: 001c01 console CPU1A

console output: not filtered

During the boot process on a system with multiple CPUs, there is a window of time in which the
CPUs are all producing output. This can result in a somewhat jumbled output from the L2.
However, you can filter console output so that the L2 will show output from only the IRU chosen
to receive console input. You can turn on filtering with the select filter on command
and turn off filtering with the select filter off command.

If you attempt to communicate with an IRU chosen to receive console input but that is not
responding, a time-out condition results:

L2> Ctrl+D

entering console mode 001c01 CPU1A, <CTRL_T> to escape to L2

no response from 001c01 Junk bus CPU1A system not responding

no response from 001c01 Junk bus CPU1A system not responding

When this time-out condition occurs, either the IRU is hung or the subchannel is not correct.