Intel OPEN (660) 120/140/150 II User Manual

Page 157

Advertising
background image

User Manual version 2.1

OPEN (660) 120/140/150

9-147

² Ripple and noise

The peak to peak ripple and noise for each output are
less than 1% of output voltage at rated load which is

measured by a 15MHz bandwidth limited
oscilloscope and each output is connected with
0.47

µ

F capacitor.

² Line regulation

The line regulation is less than +/-1% at rated load

with +/-10% change in input voltage.

² Load regulation

The load regulation for +5V is less than +/-1%, for
+12V less than +/-10%, which are measured by

changing the output load from 20% to 100% of the
rated load and the other output is kept at 60% rated
load.

G-1-3: G

ENERAL

F

EATURES

² Efficiency

The efficiency is higher than 70% while measuring at

normal line and rated load.

² Hold up time

The hold up time is longer than 16mS at 115V

AC

input and rated load

² Protection

a. Over voltage protection : The built-in crowbar

circuit will shut down the outputs to avoid

damaging the external circuits. This trip point of
over voltage protection is around 6.4V to 7.4V. To

recover from over voltage protection, cycle the AC
line OFF and ON to make it restart.

b. Short circuit protection : The power supply will

generate a hiccup mode to protect itself against
short circuit or over load conditions and will return
to normal after wrong conditions are removed.

Advertising