Power Guidelines, Requirements, and Specifications

Table 9: Component Power Requirements

Component

Power Requirement
(Watts)

Power Requirement
(Amps)

Base system (all components except PICs,
with fans running at normal speed)

188 (approximate)

4 A/48 V
(approximate)

Fans running at full speed (additional power
required)

40 (approximate)

0.833 A/48 V

Routing Engine

17

0.2 A/48 V

FEB

50

1.1 A/48 V

You can use the information in Table 9 and the M5 and M10 Internet Routers PIC Guide to
calculate power consumption for various hardware configurations, input current from a
different source voltage, and thermal output, as shown in the following examples. (For an
added safety margin, the examples use a generalized value for PICs of 0.625 A/48 V each.)

Power consumption for minimum configuration:

Base system + 1 FEB + 1 Routing Engine +

1 PIC =

4 A + 1.1 A + + 0.2 A + 0.625 A = 5.925 A @ 48 V = 284 W DC

Power consumption for maximum configuration (M5 router):

Base system + 1 FEB + 1 Routing Engine +

4 PICs =

4 A

+ 1.1 A + 0.2 A + 4(0.625 A)

=

4 A + 1.1 A + 0.2 A + 2.5 A = 9.6 A @ 48 V = 461 W DC

Power consumption for maximum configuration (M10 router):

Base system + 1 FEB + 1 Routing Engine +

8 PICs =

4 A

+ 1.1 A + 0.2 A + 8(0.625 A)

=

4 A + 1.1 A + 0.2 A + 5 A = 10.3 A @ 48 V = 494 W DC

Input current from a DC source other than 48 V (based on maximally configured M10
router; applies to DC power supply only):

(54 VDC input) x (input current X) = (48 VDC input) x (input current Y)
54 x X = 48 x 10.3 A
X = 48 x 10.3 A / 54 = 9.1 A

System thermal output for maximally configured AC-powered M10 router:

Watts DC/85% AC PEM efficiency/0.293 = BTU/hr
494/0.85/0.293 = 1984 BTU/hr

System thermal output for maximally configured DC-powered M10 router:

Watts DC/0.293 = BTU/hr
494/0.293 = 1686 BTU/hr