Details of the commands (continued), Setup commands – JVC VR-509E User Manual

Page 120

Advertising
background image

RS-232C Interface

120

SET (40H) [BASIC/JVC-1]
See ENTER (40H) on page125.

DOWN

(63H) [JVC-1]

RIGHT

(64H) [JVC-1]

LEFT

(68H) [JVC-1]

UP

(69H) [JVC-1]

Shifts the parameter settings when the timer PRG and the
alarm search parameters have been set.
Shifts the selection fields with the [UP] and [DOWN] when
the menu is being displayed.

Vol +, – (65H, 66H) [JVC-1]
Changes the set values with + (ascending) and –
(descending).

SEQ (6AH) [JVC-1]
Changes the monitor output screen mode.

MENU ON (6BH) [JVC-1]
Displays the menu.

MENU OFF (6CH) [JVC-1]
Clears the menu.

MENU ON/OFF (6DH) [JVC-1]
Switches between menu displays/clear.

ON SCREEN SELECT (74H) [JVC-1]

Switches the contents displayed on screen. (REMAIN
display is not performed when repeat recording is set at
ON.)

CANCEL (76H) [JVC-1]
Cancels the program data on the program timer setup
screen.

HDR PB CAMERA SET (86H) [JVC-1]
Specifies the playback camera. The monitor output camera
is specified during recording.
The camera that outputs images to SPOT output is
specified when in the [SPOT OUTPUT] mode.

*

FULL size sequential display, QUAD sequential display

and 6 WAY specification are invalidated when in the

playback mode (include when recording and playback

are performed at the same time).

*

The FULL size sequential display

⇔ QUAD sequential

display specifications are invalid.

*

Invalid with Second Byte: FULL size sequential display,

QUAD sequential display, 6 WAY screen and 9 WAY

specifications.

DATE SET(8EH) [BASIC/JVC-1]

Sets the month, day and year in the VR-509.

(Cannot be set when the NTP Client function is enabled, or

when the VR-509 is in the recording mode.)

TIME SET(8FH) [BASIC/JVC-1]

Sets the hours, minutes and seconds in the VR-509.

(Cannot be set when the NTP Client function is enabled, or

when the VR-509 is in the recording mode.)

MENU RESET (EFH) [JVC-1]

Initializes the menu setup values.

(Cannot be set when the VR-509 is in the recording mode,

or when the operation lock has been activated.)

3. Details of the Commands (continued)

3.3. Setup Commands

74H

1st byte

2nd byte

0AH

TXD

RXD

0AH

Second byte

Bit

Status

Detail

7

1 / 0

REC TO STOP MESSAGE : 1( ON ) / 0( OFF )

6

1 / 0

WARNING

: 1( ON ) / 0( OFF )

5

1 / 0

CAMERA TITLE

: 1( ON ) / 0( OFF )

4

1 / 0

PLAYBACK

: 1( ON ) / 0( OFF )

3

1 / 0

DISK CAPACITY

: 1( ON ) / 0( OFF )

2

1 / 0

ALARM DETECT

: 1( ON ) / 0( OFF )

1

1 / 0

ALARM COUNT

: 1( ON ) / 0( OFF )

0

1 / 0

DATE/TIME

: 1( ON ) / 0( OFF )

86H

1st byte

2nd byte

0AH

TXD

RXD

0AH

3rd byte

0AH

Second byte

Bit

Status

Detail

7 to 4 Fixed at “3”

0 / 1 / 2

3 to 0 3 / 4 / 5

6

0: FULL size specification / 1: FULL size sequential display

2: QUAD specification

/ 3: QUAD sequential display

5: 6 WAY specification

/ 6: 9 WAY specification

Third byte

Bit

Status

Detail

7 to 4 Fixed at “3”

3 to 0

8 to 0

Second BYTE: During FULL size specification

8: Camera 9 specification to 0: Camera 1 specification

Second BYTE: During QUAD specification

2: QUAD-C

1: QUAD-B

0: QUAD-A

Values that do not correspond to each setting are

invalidated.

8EH

0AH

TXD

RXD

0AH

Month

Day

Year

0AH

0AH

0AH

0AH

0AH

8FH

0AH

TXD

RXD

0AH

Hours

Minutes

Seconds

0AH

0AH

0AH

0AH

0AH

Advertising