Setting up a network for vr-509 – JVC VR-509E User Manual

Page 66

Advertising
background image

Connecting to a PC

66

Perform the initial setup procedure for the VR-509 while

referring to the connected monitor screen.

1. Press the [MENU] button.

• Opens the menus in accordance with the instructions

provided in Changing MENU Settings (page 17) in the

sequence of [MENU]

→ [OPERATION MENU] →

[NETWORK].

2. Select [HOST NAME] with the [

S/T] keys, and then

press [SET].

• The host name entry screen will be displayed.

3. Select your desired character with the [

S/T/W/X]

keys, and then press [SET].

• A single character will be entered in the host name.

* Press the [–] or [+] keys to move the cursor backward and

forward along the name.

• Press the [CANCEL] button to delete the character in the

name over which the cursor is located.

4. Select [BACK] with the [

W/X] keys, and then press

[SET].

• The screen will return to the [NETWORK] screen.

5. Select your desired item with the [

S/T/W/X] keys, and

then change the value of the setting with [–/+].

* The factory default settings are listed below.

• METHOD: STATIC IP (DHCP servers cannot be used.)

• IP ADDRESS: 192.168.0.10

• NET MASK: 255.255.255.0

• DEFAULT GATEWAY: 192.168.0.254

Consult with the network administrator for details on the

settings required to connect the recorder to a LAN network.

6. Press the [SET] button.

• The settings will be saved.

• When a DHCP server has been set for METHOD, the IP

address allocated by the DHCP server will be displayed

the next time this menu is opened (cannot be amended).

• When [DHCP] has been set for METHOD, the IP

address acquisition process will only be performed when

the recorder is rebooted or when the setting is amended

to an IP address. If the network is enabled after a certain

period of time has passed since rebooting, amend the

METHOD setting to something different, and then

change it back to [DHCP] in order to acquire the IP

address.

• If setting acquisition from the DHCP server failed with

[DHCP] set as the setup method, the previous STATIC

IP values will be set.

* Press the [RETURN] button to return to the previous screen.

Setting up a Network for VR-509

NETWORK

HOST NAME..
METHOD
IP ADDRESS
NET MASK
DEFAULT GATEWAY
DNS SERVER

MAC ADDRESS

vr509

STATIC IP

192.168. 0. 10

255.255.255. 0
192.168. 0.254

0. 0. 0. 0

00:80:88:40:b0:00

2.

HOST NAME:

***** ***** ***** ***** ***** *****

BACK

***** ***** ***** *****

***** ***** ***** ***** ***** *****

3.

4.

Advertising