Juniper Networks E-Series User Manual

Page 126

Advertising
background image

CHAPTER 10
Troubleshooting

10-4

The following figures show a representative module for each of the three
variations:

SRP module (

Figure 10-1

)

Ethernet line
modules

LINK

Ethernet

Green

Ethernet link up

Ethernet link down

ACTIVITY

Ethernet

Green

Blinks when Ethernet
traffic on link

No Ethernet traffic
on link

HSSI line
module

SYNC

Port status

Green

If the port is configured
as DTE, the LED lights
when both the DCE and
the clock source are
available.
If the port is configured
as DCE, the LED lights
when the DTE is
available.

If the port is configured
as DTE, the LED goes
out when either the DCE
or the clock source
becomes unavailable.
If the port is configured
as DCE, the LED goes
out when the DTE
becomes unavailable.

YEL ALM

Note: This LED is not functional on the HSSI line module.

RED ALM

Port status

Red

If the port is configured
as DTE, the LED lights
when either the DCE or
the clock source
becomes unavailable.
If the port is configured
as DCE, the LED lights
when the DTE becomes
unavailable.

If the port is configured
as DTE, the LE goes out
when both the DCE and
the clock source are
available.
If the port is configured
as DCE, the LED goes
out when the DTE is
available.

X.21/V.35 line
module

ACTIVE

Port status

Green

Port configured

Port not configured

LOOPBK

Port status

Yellow

Port in local loopback or
remote loopback,
depending on the type of
connection. (See)

Port not in loopback

ERROR

Port status

Red

Port is enabled or comes
online

Port is disabled or goes
offline

V.35

Port status

Green

V.35 cable connected

V.35 cable disconnected

X.21

Port status

Green

X.21 cable connected

X.21 cable disconnected

DCE

Port status

Green

DCE cable connected

DCE cable disconnected

DTE

Port status

Green

DTE cable connected

DTE cable disconnected

Other line
modules

SYNC

Port status

Green

In frame

Not in frame

YEL ALM

Port status

Yellow

Far end receive failure
(FERF) exists

No FERF present

RED ALM

Port status

Red

Loss of sync/frame

In frame

Table 10-2 LED identification and activity descriptions (continued)

LED Location LED Label

LED Indicator LED Color OFF to ON

ON to OFF

Advertising