Powering Up E-Series Routers

7-2

Powering Up

Note: This procedure assumes that the system is already connected to a power
source. See

Chapter 6, Cabling the E-Series Router for Power

.

For specifications on the electrical requirements for the system, see

Chapter 11, System Specifications

. For details on the power consumed by

the different E-series modules, see

Chapter 12, Module Specifications

.

Branch Circuit Caution: Evaluate the overall loading of the branch circuit before
you install any equipment into a rack.

To power up the system:

1

Verify that the power source is operational and turned on.

2

Inspect all grounding and power connections to the E-series chassis.

3

Confirm that all connections are secure.

4

Switch the power switches to ON.

5

Monitor the LEDs on the front of the SRP modules to verify that the
system is booting properly. See

Table 10-2

in

Chapter 10,

Troubleshooting

. for LED status explanations.

When the prompt appears on the system console, the system is in
User Exec mode and is ready to be configured:

host1>

6

Enter the

enable command to access Privileged Exec mode:

host1>enable

host1#

In Privileged Exec mode you can begin to configure the system. See
the

E-Series System Basics Configuration Guide, Chapter 2,

Command Line Interface

for more information.

Warning: Be sure the power source is turned off and the system is turned off
before performing the following task.

Connect DC power or AC power to your E-series router.
(depending on model)

6-9

Cable all line modules.

6-14

Table 7-1 Installation tasks (continued)

Installation Task