ERX-7xx Models Specifications

E-Series Routers

11-3

ERX-7xx Models Specifications

Telecommunications
Certification

•

ACA TS 016-1997

•

CTR13 – Commission Decision of 9 July 1997 on a common technical
regulation for attachment requirements for terminal equipment interface for
connection to 2048 kbit/s digital structured ONP leased lines: 97/521/EC –
OJ No. L215 Vol. 40, August 1997

•

CTR24 – Commission Decision of 9 September 1997 on a common
technical regulation for attachment requirements for terminal equipment
interface for connection to 34 Mbit/s digital unstructured and structured
leased lines: 97/639/EC – OJ No. L271 Vol. 40, 3 October 1997

•

FCC PART 68

•

IECS-003 Issue 3 Class A

•

PD7024 – Essential requirements for terminal equipment intended for
connection to unstructured digital leased circuits of the public
telecommunications network using a CCITT recommendation G,703
interface at a rate of 2048 kbit/s with a 75 ohm unbalanced presentation,
1994

•

RTTE Directive (1999/5/EEC)

a.If the voltage rises above –40 VDC, the system will power off. The system will not power on again until the input

voltage reaches –43 +/– 0.5 VDC.

Table 11-1 ERX-14xx models specifications (continued)

Category

Specification

Table 11-2 ERX-7xx models specifications

Category

Specification

Weight
Chassis only
Chassis fully configured

22 lb

9.9 kg

46 lb

20.7 kg

Dimensions

10.5 (H) x 19 (W) x 16 (D) inches; 26.67 x 48.26 x 40.64 cm

Environmental Requirements
Ambient operating temperature

Ambient operating humidity

Ambient storage temperature
Ambient storage humidity

NEBS GR-63-CORE compliant
•

Long term: 41

°

to 104

°

F (5

°

to 40

°

C)

Short term: 23

°

to 122

°

F (–5

°

to 50

°

C)

•

Long term: 5% to 85% (noncondensing)
Short term: 5% to 95% (noncondensing)

–40

°

to 158

°

F (–40

°

to +70

°

C), 95% relative humidity

5% to 95% (noncondensing)

Heat Dissipation

1400 W, 4780 BTU/hour maximum

Space Requirements

•

3 feet (90 cm) behind router or rack

•

Do not block air vents on sides of the router.

•

Do not place equipment that exhausts hot air to left on the right of the router.

•

Be aware that router exhausts hot air from its left side.