Required Tools, Wires, and Cables

Cabling your system should take only a few minutes. You will need the
items listed below and in

Table 6-1

for proper installation.

1/8" flathead screwdriver

3/8" wrench or 3/8" nut-driver

No. 2 Phillips screwdriver

Ground wires – We recommend a minimum of 10-AWG ground wire.

#10 (ERX-7xx/14xx models) or #8 (ERX-310 router) kep nut to
connect the ground (earth) wire to the ground terminal.

Power input module wiring – We recommend a minimum of 10-AWG
(ERX-7xx/14xx model) or 14-AWG (ERX-310 router DC model) wire
with a dual stud terminal lug with 3/8" spacing. For the ERX-310
router AC model, use a standard IEC power cord.

Note: If you plan on using a cable-management bracket (ERX-7xx/14xx models
only), install it before you begin cabling your E-series router. Cable-management
brackets are helpful to keep network interface cables untangled and orderly and to
prevent cables from hindering access to other slots. See

Installing a

Cable-Management Bracket on ERX-7xx Models

in

Chapter 9, Maintaining

E-Series Routers

.

Table 6-1 Required cables

Connection

Port and Cable Used

Management connection between SRP
I/O module and the LAN

One 10/100Base-T Ethernet management
port with an RJ-45 connector

Management connection between SRP
I/O module and a management console

One RS-232 port with a DB-9 connector for
VT100 management access

Direct connections to I/O modules

See

Table 12-3

in

Chapter 12, Module

Specifications

for specific I/O module