CHAPTER 11
System Specifications

11-6

Space Requirements

3 feet (90 cm) behind router or rack

Do not block air vents on sides of the router.

Do not place equipment that exhausts hot air to left on the right of the
router.

Be aware that router exhausts hot air from its left side.

Airflow

Airflow direction is in through the right side and out through the left side.
See

Figure 3-2

in

Chapter 3, Installation Guidelines and Requirements

.

DC Input
Voltage
Current
Power
Redundancy (input power)

–40 to –72 VDC

a

9 A @ –48 VDC
500 W maximum
2 independent line feeds

AC Input
Power required
AC line frequency
Power

90-265 VAC @ ~5 A
50-60 Hz
500 W

NEBS Certification

Not yet available for the ERX-310 router

Safety Agency Certification

AS/NZS 3260:1993, Safety of Information Technology Equipment
Including Electrical Business Equipment

CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information
Technology Equipment

EN60825-1, Safety of Laser Products - Part 1: Equipment Class,
Requirements, and User’s Guide (2001)

EN60950:2000, 3rd Edition, Safety of Information Technology
Equipment

IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment -
Safety - Part 1: General requirements

Low Voltage Directive (73/23/EEC)

UL 60950, 3rd Edition, Safety of Information Technology Equipment

Electromagnetic Emissions
Agency Certification

AS/NZS 3548:1995 (CISPR 22 Class A)

EMC Directive (89/336/EEC)

EN55022 Class A (CISPR-22 Class A)

EN55024, Annex C for WAN Equipment Performance Criteria A, B, and
C

ETSI 300-386, Telecommunication Network Equipment;
ElectroMagnetic Compatibility (EMC) requirements

FCC Part 15 Class A

IECS-003 Issue 3 Class A

VCCI (Voluntary Control Council for Interference by Information
Technology Equipment)

Table 11-3 ERX-310 router specifications (continued)

Category

Specification

Advertising