Led activity during booting, Abnormal led activity, Ation, see – Juniper Networks E-Series User Manual

Page 129: Table 10-4

Advertising
background image

Understanding Status LEDs to Troubleshoot

E-Series Routers

10-7

LED Activity During Booting

When the system boots, it runs diagnostic tests, and the module status
LEDs display various configurations. Observe the scenario presented in

Table 10-3

to verify that the system has booted properly.

Note: When you reboot the system after installing a new version of the software,
the line modules will appear to boot twice.

If the system detects an error during booting, the FAIL LED turns on.
Some failure conditions may cause the board not to boot. In this case, the
LEDs may all be off. The system should then reset the board.

If the operational software detects an error, the FAIL LED turns on.
Some errors may cause a board reset. Crash information can be displayed
from the console and is printed to the screen on the next reboot.

Abnormal LED Activity

See

Table 10-4

to diagnose and correct problems.

Table 10-3 Normal activity of functional status LEDS during booting

OK

FAIL

ONLINE

Status Process

off

on

off

1 Module is in the power-up restart state; the FAIL

LED stays on briefly.

off

off

off

2 Module is initializing, and diagnostic tests are

running.

on

off

off

3 Module passed the diagnostics; the system boots.

on

off

on

4 Module is now up and running.

Table 10-4 Troubleshooting abnormal LED activity on modules

Diagnostic Signs

Possible Problems

Actions

POWER A OK is not lit

POWER B OK is not lit

System is not receiving
power from Power A.

System is not receiving
power from Power B.

1 Check Power A and Power B terminal connections.
2 Verify that power switches are on.
3 Check connections to power sources.
4 If system still does not operate, contact Juniper

Networks Customer Service.