Auto pan setting, An settings – JVC VN-C625 User Manual

Page 102

Advertising
background image

102

Operations (Step 5 Operating Using a Web Browser)

Alarm In

For specifying the camera operation upon
input of alarm signals.

1

IN1/IN2

On

: Detect Mode

(Set value: Make, Break, Toggle)

: Alarm Out

(Set value: Not Available, OUT1, OUT2)

: Go to a Preset Position

(Set value: Not Available, Home,
Position 1 to Position 99)

: Return Mode

(Set value: Not Available, Return, Event)

: Return Interval

(Set value: 1 to 65535 seconds)

: Black & White

(Set value: Not Available, Color, Black
& White, Auto)

: Message Packet

(Set value: Available, Not Available)

: FTP

(Set value: Available, Not Available)

: Shutdown

(Set value: Available, Not Available)

Off

: Do not use Alarm 1 and Alarm 2.

2

Relay Alarm

On

: Alarm Out

(Set value: Not Available, OUT1, OUT2)

: Go to a Preset Position

(Set value: Not Available, Home,
Position 1 to Position 99)

: Return Mode

(Set value: Not Available, Return, Event)

: Return Interval

(Set value: 1 to 65535 seconds)

: Black & White

(Set value: Not Available, Color, Black
& White, Auto)

: Message Packet

(Set value: Available, Not Available)

: FTP

(Set value: Available, Not Available)

: Shutdown

(Set value: Available, Not Available)

Off

: Do not use Relay Alarm.

Other Triggers

For setting alarm activation via methods other
than alarm input.

3

Preset Position

On

: Alarm Output

(Set value: Not Available, OUT1, OUT2)

: Black & White

(Set value: Not Available, Color, Black
& White, Auto)

: Massage Packet

(Set value: Available, Not Available)

Off

: Do not use "Preset Position" Alarm.

4

Black & White

On

: Alarm Out

(Set value: Not Available, OUT1, OUT2)

: Go to a Preset Position

(Set value: Not Available, Home,
Position 1 to Position 99)

: Return Mode

(Set value: Not Available, Return, Event)

: Return Interval

(Set value: 1 to 65535 seconds)

: Massage Packet

(Set value: Available, Not Available)

Off

: Do not use Black & White Alarm.

Alarm Out

For performing setting related to output during
an alarm activation.

5

OUT1/OUT2

On

: Output Value

(Set value: ON, OFF)

: Pattern

(Set value: Level, Momentum)

: Momentum Interval

(Set value: 1 to 5000 milliseconds)

Off

: Do not output alarm.

5-4 Setting Using the Web Browser (7. Alarm Setting) (Continued)

Notes

● Set output settings according to settings of

the device for which alarm output is sent to.

● When alarm setting is complete, always

check to ensure that the alarm is functioning
correctly.

C625_p95-p114

05.3.4, 6:56 PM

102

Advertising