1

Alarm 1/Alarm 2
Message Packet

Alarm FTP

Shutdown

2

Relay Alarm

• Alarm Output
• Go to a preset position
• Return Mode
• Interval
• Black & White
• Message Packet
• Alarm FTP
• Shutdown

3

Retry (1 to 3)

Item

Function/Set Value

(Continued)
For setting whether to send alarm packets to the PC when there
is alarm input.

Not Available

: Do not send alarm packets.

Available

: Send alarm packets.

For operation according to the [Alarm FTP] in the FTP Client
feature when there is alarm input. Please refer to FTP Client
Settings (

Page 50) for details on alarm FTP.

Set Values: Available, Not Available
Set to "Available" to quit all operations upon alarm input. Using
this Shutdown function enables operations of this camera to
end safely even during recording into CF cards.

Not Available

: Do not shut down.

Available

: Shut down.

Set here to enable the relay alarm function, which is activated
when 2 alarms are received within a preset time interval.
The sequence and time interval for the alarm input can be specified.
When [Alarm Output] is selected, alarm signal output will be
sent to the alarm output terminal on the ceiling mount accord-
ing to the output port settings.

* Please refer to the [Alarm 1/2] item for details on the set val-

ues.

For setting the no. of times alarm notification is to be sent to
the "V.Networks Controller". (Set Value: 1 to 3)

Initial Value

Not Available

Not Available

Not Available

Not Available

*Please

refer to
the [Alarm
1/2] item
for the
initial
values.

1

Note

• When this is set to "Available", all alarm input except alarm

output and message packets will be disabled.

Note

• Alarm notification may fail, depending on the LAN

environment in use. If it fails, set the value for alarm
notification to "3". In this case, alarm by the "V.Networks
Controller" itself is set off only once.

Notes

• A second alarm input enables this relay alarm function,

and alarm will not be activated for this second input.

• Unless the alarm output in the "Alarm Output" tab is

enabled, this function will not be activated even if alarm
output is selected in the alarm input settings. (

Page 41)

C625_p25-41

05.3.4, 8:10 PM

39