17

Alarm Output Terminal

Connect this terminal to alarm devices such
as an annunciator, indicator, lamp or buzzer.

Output Requirements

• Equivalent to NPN open collector output (Set

output logic using the controller)

• Allowed applied voltage: DC12V and below
• Allowed input current: 50 mA
• Momentary output: 1 to 5000ms (Set duration

using the controller)

3. Connection of LAN Cables

Use the LAN cable to connect this camera
to a hub or PC

When connecting to a hub
make use of a straight cable.
When connecting to a PC
make use of a cross cable.

IN

R

DC 12 V

GND

VN-C625

OUT
Terminal

Alarm Device
Connection
Example

(Alarm Output
Equivalent Circuit)

Grounding
Terminal

Note

When using 100 BASE-TX, ensure to use a Category 5 (or higher) cable.

Caution

Connect the grounding terminal of VN-C625
to the GND terminal of the alarm device.

Caution

The use of a cross cable may not be
supported by certain LAN boards on some
rare occasions. As such, please check your
LAN board specifications before connection.