Behaviour regarding the survivability settings, Backup server not entered and activated, Backup server is entered, but not activated – Siemens HIPATH 8000 User Manual

Page 101: Backup server is entered and activated

Advertising
background image

Extended Administration

101

Behaviour regarding the Survivability settings

Please make sure all parameters are set completely and accurately.

Backup Server not entered and activated

• Backup IP address or DNS name:

No IP address was entered (Æ page 219

,

Æ

page 147)

• Backup registration:

– The Checkbox for the "Backup registration" feature is not marked

(Æ page 147) and/or the feature was not activated in the telephone
menu (Æ page 220)

The telephone only registers at the server (Hipath8000). In case the server

fails or is not available, the message "Server not found" is displayed. No

calls can be made.

Backup Server is entered, but not activated

• Backup IP address or DNS name:

– IP address is entered (e.g. 192.168.1.1 Æ page 219

,

Æ

page 147)

• Backup registration:

– The Checkbox for the "Backup registration" feature is not marked

(Æ page 147) and/or the feature was not activated in the telephone
menu (Æ page 220).

The telephone only registers at the server (Hipath8000). In case the server

fails or is not available, no message is displayed. Even after restarting the

telephone no message is displayed, and the display looks as if the tele-

phone had registered at the HiPath8000. However, outbound calls are pos-

sible via the backup server, while inbound calls to this telephone are not

possible as it is not registered at the backup server.

Backup Server is entered and activated

• Backup IP address or DNS name:

– IP address is entered (e.g. 192.168.1. Æ page 219

,

Æ

page 147)

• Backup registration:

– The Checkbox for the "Backup registration" feature is marked

(Æ page 147) and the feature is activated in the telephone menu
(Æ page 220).

The telephone registers both at the server (Hipath8000) and the backup

server. In case the Hipath8000 fails or is not available, the message "Tem-

porary limited mode" is displayed. Both outbound and inbound calls are

possible via the backup server..