Time zone offset, Timer high priority, Timer medium priority – Siemens HIPATH 8000 User Manual

Page 225: Transaction timer, Timezone offset

Advertising
background image

Alphabetical Reference

225

Time zone offset

• The specification describes the shift in hours corresponding to the time

zone information of the SNTP server.

• Make an entry only if an Æ SNTP server provides time zone informa-

tion.

• Value range table:

• Editing by phone: Offset Editor Æ page 161.

Æ page 67

Æ

page 120

Timer High Priority

Set the delay in seconds after the last high priority item change before sav-

ing the changes to the DLS.

• Causes time out before saving high prioity user data.

• Vaulue range: 0 to 999

Æ page 102

Æ

page 134

Timer Medium Priority

Set the delay in seconds after the last medium priority item change before

saving the changes to the DLS. Used in confjunction with the Medium Pri-

oity peg count threshold.

• Timeout before saving medium priority user data

• The value has to be a number in the range 1 to 999

Æ page 102

Æ

page 134

Transaction timer

The Transaction Timer sets the amount of time that the phone will wait for

a response to any SIP request that it sends. The time value is in millisec-

onds and the user can enter any value between 3000 and 32000. The de-

fault value is 32000 milliseconds.

Æ page 66

Æ

page 115

Permitted values

numeric

min.

-12

max.

+12

Default value

0

Advertising