Integrating the Solar Inverter

in the PV System

Rating of the PV Generator

The technical data of the selected PV

generator must be compatible with the

specification of the Solar Inverter (see

Technical Data). An incompatible rating

may reduce the yield or destroy the

device. The rating program Sunways NT

Sundim can help you select the correct PV

generator rating. You will find Sunways

NT Sundim on the enclosed CD ROM or

on our homepage www.sunways.de.

Prior to planning your system, please take

the following considerations into account:

· Mind the orientation of the modules.

In Central Europe, you will gain a maxi-

mum yield if the module has a horizon-

tal angle of 30° and the PV generator

field points directly towards the south.

· The warmer the module gets, the smal-

ler the output of the cells will be.

Therefore, make sure your PV generator

has sufficient back ventilation when you

install it.

· Check your PV generator for contami-

nation approximately every three years.

Contamination mostly occurs on the

lower edge of the module; it forms a

veil that is not even washed off by

heavy rain. A loss of yield can be pre-

vented by cleaning the modules with a

wet cloth or a brush.

· Make sure none of the modules or solar

cells of your system are in the shade.

That may lead to a significant loss of

yield.

· The NT 10000 has three internal energy

units that are supplied by three inde-

pendent PV generators. The NT 10000 is

based on the «MPP multitracking» prin-

ciple; i. e. each inlet has its own MPP

controller.