4.3 Technical Data NT 10000

Solar Inverter NT 10000

Recommended solar generator output

Nominal input
Standby consumption
Night consumption
Injection starts from
Nominal voltage
UMPP voltage range
No-load voltage
Turn-on voltage
Turn-off voltage
Maximum current
Nominal current
Number of inlets

Maximum efficiency level
European efficiency level (weighted)
HERIC® topology

Nominal output continuous operation Pn
Maximum output Pp
Nominal frequency
Grid voltage
Grid voltage tolerance range
Nominal current per phase
Max. current per phase
Distortion factor with Pn
Reactive power factor (cos phi)
Current waveform

Model

7000–12000 Wp

11000 W
20 W
< 0.3 W
7 W
400 V
350 <= UMPP <= 750 V
850 V
420 V
340 V
10 A per MPP multitracking inlet
9 A per MPP multitracking inlet
1 per MPP multitracking inlet;
3 altogether

96.4 percent (with ventilator operation)
95.9 percent (with ventilator operation)
yes

10000 W
10000 W
50 Hz
400 V
-20 to +15 percent
14.5 A
18.2 A
< 3 percent
approx. 1
sine