background image

151

Error

Error 038

Back-up battery

empty

Display is blank,

despite sufficient

injection

Causes

The back-up battery on the

interface circuit board is

empty.

The display contrast is bad,

because the temperature is

high.

The display circuit board is

not supplied with electricity.

The PV generator is (partly)

covered with snow.

Remedies

Have the battery (button cell) exchanged

by a qualified person. The battery is on

the LCD display circuit board.

That can happen if the ambient tempera-

ture is high. As soon as the temperature

drops, the display will work properly

again. That does not affect the injection

of electricity.

Make sure the ribbon cable between

the display circuit board and the control

circuit board is not loose. For this pur-

pose, switch the Solar Inverter off, and

disconnect the AC and DC supply.

When doing so, please observe chapter

2.1 «Safety Instructions».

Clear the snow off the PV generator,

or wait until it has melted.