Connecting the Insolation and

Temperature Sensor

The optional insolation sensor (type

Si-01TC-T by Ing.-Büro Mencke & Tegt-

meyer) with its integrated PT-100 tempera-

ture probe for measuring the temperature

lets you record the insolation data and the

corresponding module temperature and

store them in the internal data memory

as a 15-minute average value.

This additional measuring unit helps you

analyse the performance of the system.

Based on the values, any faults in the PV

generator, e. g. shaded or defect solar

cells, can be detected.

Prior to connecting an insolation sensor,

move the cover of the Solar Inverter up,

and fix it in position by tightening a late-

ral screw. Please note that the inlets and

outlets are not short-circuit-proof. Please

observe chapter 2.1 «Safety Instructions».

The optional insolation sensor with the

temperature probe is connected to the

cable terminal block «X4» in the lower

section of the circuit board.

Illustr.: Connection insolation sensor