Sunway NT 10000 User Manual

Page 71

Advertising
background image

With Tyco Solarlok connectors, different

kinds of annular contacts are used for dif-

ferent conductor cross-sections. Make sure

to use the right tools for these cross-sec-

tions. The enclosed Tyco Solarlok connec-

tors are equipped with annular contacts

for a cable cross-section of 4 mm. The

enclosed seals have an internal diameter of

6 mm (for lines with a cladding diameter

of 5.3 to 6.2 mm) and 8 mm (for lines with

a cladding diameter of 7.2 to 8.0 mm).

Make sure to use a seal that fits the clad-

ding diameter of the cable used.

When installing the Tyco Solarlok connec-

tors, proceed in the following order:

1. Bare the de-energised line by 8 mm

2. Crimp the annular contact

3. Slide the gland, the compression sleeve,

and the seal onto the line

4. Engage the contact in the connector

housing

5. Screw the lock nut on

6. Tightening torque for the cable gland:

1.5 Nm