Maintenance and Cleaning

Follow these steps to replace the lamp.

Lamp

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.

Model No. of your projector

:

PLC-XL40

Replacement Lamp Type No.

:

POA-LMP90

(Service Parts No. 610 323 0726)

For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.

Allow the projector to cool for at least 45 minutes
before you open the Lamp cover. The inside of
the projector can become very hot.

CAUTION

Screw

Turn off the projector and unplug the AC power cord.
Let the projector cool for at least 45 minutes.

Remove the two screws that secures the lamp. Lift
the lamp out of the projector by using the built in
handle.

1

3

Replace the lamp with a new one and secure it with
the two screws. Make sure that the lamp is set
properly. Put the lamp cover back and secure it with
the screw.

4

Turn the projector over. Remove the screw that secure
the lamp cover, and then open the lamp cover.

2

Connect the AC power cord to the projector and turn
on the projector.

6

Reset the lamp replacement counter.
See “Lamp Replacement Counter” on the next page.

5

Handle

Screw

CAUTION

Screw

Lamp Cover

When the projection lamp of the projector reaches the end
of its life, the LAMP REPLACE indicator emits a yellow
light. If this indicator lights yellow, replace the lamp with a
new one promptly.

Top Control

Lamp Replacement

WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER

REPLACE

POWER

WARNING

LAMP

This indicator turns yellow
when the projection lamp
reaches the end of its life.