Connected equipment

Use the



buttons to select the type of system to which they are connected or the single-cable

system components fi tted (refer to the manuals, instructions and notes for the system and the system
components). Available options:

- user-defi ned
-

KATHREIN UAS 481 (single-cable feed system, max. four receivers)

-

KATHREIN EXR 551 (single-cable switching matrix, max. four receivers applies also for EXR 501)

-

KATHREIN EXR 552 (single-cable switching matrix, max. four receivers)

-

KATHREIN EXU 908 (single-cable matrix, max. eight receivers)

-

EXR 4 subscriber

(for future Kathrein single-cable (switching) matrices, max. four receivers)

-

EXR 8 subscriber

(for future Kathrein single-cable (switching) matrices, max. eight receivers)

Selection “user-defi ned”

Transmission channel

Use the



buttons to select a free available transmission channel.

Transmission frequency

Use the number buttons to input the four-digit transmission frequency.

FIRST INSTALLATION: Single-cable system (manual)

If one or more receivers are
already present on the system
and an additional receiver is to
be connected, you must assign
the new receiver a transmission
frequency that is not already in
use (otherwise the receivers will
interfere with each other).
Depending on the system to which
they are connected, a maximum
of four or eight receivers may be
connected to a single-cable system
(a twin receiver counts as two
receivers).

No frequency can be used by more than one receiver.
The receivers would interfere with each other.
You can fi

nd the necessary information (transmission frequencies) in the

documentation supplied with your system.